Veröffentlichungen des Instituts
Literaturverweise
Literatur- und Veröffentlichungsliste
Vorträge
- R. Rawer:
Vergleich der Abbildungsqualität hydrophober Acryl-Intraokularlinsen mit und ohne Blaulichtfilter vor und nach der Injektion durch eine Kartusche
Symposium: Hydrophobe Acryl-Intraokularlinsen mit und ohne Blaulichtfilter, Internationaler Erfahrungsaustausch über eine neue Generation von Intraokularlinsen, Wien, Oktober 2004
- R. Rawer, W. Stork, C. Lingenfelder, C.W. Spraul:
Analysis of the optical imaging quality of foldable Intra Ocular Lenses (IOL) before and after injection through a cartridge by comparative measurement of the Point Spread Function (PSF) according to ISO Standard,
XXII Congress of the European Society of Cataract and Refractive Surgeons, Paris, 2004
- R. Rawer, W. Stork, C. Lingenfelder, C.W. Spraul:
Comparative measurement of the optical imaging quality of foldable Intra Ocular Lenses (IOL) by analysis of the Point Spread Function (PSF) according to ISO Standard before and after injection through a cartridge,
102. Jahrestagung der Deutsche Ophthalmologische Gesellschaft (DOG), Berlin, 2004
Buchbeiträge
- [Rawer05b] R. Rawer:
Vergleich der Abbildungsqualität hydrophober Acryl-Intraokularlinsen mit und ohne Blaulichtfilter vor und nach der Injektion durch eine Kartusche
Symposium: Hydrophobe Acryl-Intraokularlinsen mit und ohne Blaulichtfilter, Herausgeber S. Binder, R. Welt, R.D. Gerste, ad manum medici Verlag für Medizin und Naturwissenschaften, Germering, ISBN 3-928027-25-5, 2005, s.15-24
Zeitschriftenbeiträge
- [Rawer05c] R. Rawer, W. Stork, C. Lingenfelder, C.W. Spraul:
Comparative measurements of the imaging quality of foldable Intraocular Lenses by analysis of the point Spread Function (PSF) according to ISO requirements before and after injection through a cartridge
Graefe's Archive for Clinical and Experimental Ophthalmology, submitted August 2004
- [Spraul05] C.W. Spraul, R. Rawer, W. Stork, P. Walther, C. Lingenfelder, G.K. Lang:
Spielt die Orientierung einer IOL im Auge eine Rolle?
Klinische Monatsblätter für Augenheilkunde, submitted January 2005
- [Rawer05a] R. Rawer, W. Stork:
Imaging Quality of Intraocular Lenses,
ESCRS, Journal of Cataract & Refractive Surgery, 31/8:1618-163, August 2005
- [Eisenmann93] D. Eisenmann, V. Hessemer, B. Manzke, W. Stork, K.W. Jacobi:
Modulationsübertragungsfunktion und Kontrast-empfindlichkeit refraktiver Mehrzonenmultifokallinsen
Ophthalmologe, 90:343-347, 1993
zum Seitenanfang
| [Akutsu93] |
Akutsu, H., Legge, G.E., Luebker, A., Lindstrom, R.L., Zabel, R.W., Kirby, V.M.:
Multifocal Intraocular Lenses and Glare
Optometry and Vision Science, AAO, 1993, 70/6:478-95 |
| [Brennan97] |
Liou, H-L, Brennan:
A. Anatomically accurate, finite eye model for optical modeling
J. Opt. Soc. of America. A., 1997, A14/8:1684-95 |
| [Brennan04] |
Liou, H-L, Brennan:
Eye model for the prediction of contrast vision in patients with new intraocular lens designs
Optics Letters, OSA, 2004, 29/7:733-35 |
| [Charman96] |
Charman, W.N.:
Handbook of Optics Volume I.
McGraw-Hill, 1996, 24.17-18 |
| [Hecht98] |
Hecht, E.:
Optik
Oldenbourg Verlag, 1998, 6.3 |
| [Holladay87] |
Holladay, J.T., King, A.C., Koester, C.J.:
Intraocular lens resolution in air and water
J. Cataract Refract. Surg., 1987, 13:511-517 |
| [Holladay88] |
Holladay, J.T., King, A.C., Koester, C.J.:
Silicone intraocular lens resolution in air and water
J. Cataract Refract. Surg., 1988, 14:657-659 |
| [Holladay93] |
Holladay, J.T. et.al:
Intraocular lens performance in air, in water and in situ: a computer study
J. Cataract Refract. Surg., 1993 , 19:499-504 |
| [Holladay02] |
Holladay, J.T. et.al:
A New Intraocular Lens Design to Reduce Spherical Aberration of Pseudophakic Eyes
J. Cataract Refract. Surg., 2002, 18:683-691 |
| [ISO9334] |
EN/ISO 9334:
Optical Instrument – Optical Transfer Function – Definitions and Mathematical Relationsships
2002 |
| [ISO9335] |
EN/ISO 9335:
Optical Instrument – Optical Transfer Function – Principles and Procedures of Measurement
2002 |
| [ISO11979] |
EN/ISO 11979-2:
Ophthalmic implants – Intraocular lenses – Part 2: Optical properties and thest methods
1999 |
| [Knorz92] |
Knorz, M.C. et.al.:
Comparison of modulation transfer function and through focus response with monofocal and bifocal IOLs
Ger. J. Ophthalm., 1992, 1:45-53 |
| [Norrby98] |
Norrby, N.E., Patel, A.S., Silberman,D.M., et.al.:
Determining the imaging quality of intraocular lenses
J. Catarcat Refract. Surg., 1998, 24:703-14 |
| [Oshika99] |
Oshika, T., Klyce, S.D., Applegate, R.A., Howland, H.C.:
Changes in Corneal Wavefront Aberrations with Aging
Inv. Ophthalmo. & Vis. Science, 40/7:1351-55, 1999 |
| [Oyster99] |
Oyster, C.W.:
The Human Eye – Structure and Function, Sinauer Associates
ISBN 0-87893-645-9, 1999 |
| [Piers04] |
Pier, A., Norrby, N.E.S.:
Eye models for the prediction of contrast vision in patients with new intraocular lens designs
Optics Letters, OSA, 2004, 29/7:733-35 |
| [Schwieger00] |
Schwiegerling, J.:
Theoretical Limits to Visual Performance
Survey of Ophthalmology, 2000, 45/2:139-46 |
| [Tognetto04] |
Tognetto, D.T. et.al.:
Analysis of the Optical Quality of Intraocular Lenses
Inv. Ophthalmol. & Vis. Sc. (IOVS), 2004, 45/8:2682-90 |